  1. This README file of PS2CMB.ZIP for NetWare v2.2 and v2.15C.
  2. The following files are included for this revision:
  3.  
  4.     COMB     OBJ    12645   5-23-91   1:59p
  5.     DUMMY    OBJ      138   5-23-91   1:59p
  6.     SCSICOMB DSK      564   9-10-91  10:20a
  7.     ESDICOMB DSK     1292   9-10-91  10:22a
  8.  
  9. Novell ESDI/SCSI Combination Driver Set
  10.  
  11.             WARNING: Before you begin this installation, back up your  
  12.                      system to avoid losing any important data.
  13.  
  14.             If you are installing on a v2.2 network, use the Advanced
  15.             installation.  Do not use Basic Install. 
  16.  
  17.             To install the new ESDI/SCSI combination driver set in
  18.             your PS/2 Model, complete the following steps: 
  19.  
  20.             1.    Follow the instructions for installing drives and
  21.                   disk controllers in your IBM documentation. 
  22.                   Don't autoconfigure the system. Continue with Step 2.
  23.  
  24.             2.    Run REFERENCE. 
  25.  
  26.             3.    From the main menu, choose Option #2 ("Set
  27.                   Configuration")
  28.  
  29.             4.    From the "Set Configuration" menu, choose Option #1   
  30.                   ("View Configuration") and record the following          
  31.                   information:
  32.  
  33.                   o     I/O addresses 
  34.  
  35.                   o     DMA 
  36.  
  37.             5.    From the "Set Configuration" menu, choose
  38.                   Option #6 ("Set and View SCSI device
  39.                   configuration").
  40.  
  41.                   Check to be sure the SCSI configuration matches your
  42.                   recorded configuration information. 
  43.  
  44.             6.    When configuration is completed, choose Option #7
  45.                   ("Display Memory Map").
  46.  
  47.                   Record the hexadecimal addresses for each driver
  48.                   as shown on the screen. 
  49.  
  50.       Note: If your system includes more than 2 hard drives and you are
  51.             running DOS 4.0, you must install the DOS v4.0 Corrective   
  52.             Services Diskette (CSD #UR29015). This diskette is available 
  53.             from IBM.  The system must be booted with DOS 4.0 or      
  54.             higher.
  55.  
  56.             7.    Follow the instructions on the screen to exit             
  57.                   REFERENCE.
  58.  
  59.             The following installation instructions are divided into two    
  60.             categories:
  61.  
  62.             o     v2.15
  63.  
  64.             o     v2.2
  65.  
  66.             Scroll through to find the section that applies to your specific 
  67.             system.             You are now ready to begin the installation process. These
  68.             procedures vary between v2.15 and v2.2 systems. There are   
  69.             no defaults available for this installation.  You must load the 
  70.             ESDI and the SCSI shared int 14 drivers.  The operating     
  71.             system will be unable to link if both drivers are not loaded.
  72.  
  73.       Note: All driver configuration options must correspond to
  74.             actual hardware settings.  Software adjusts must be           
  75.             accompanied by hardware adjustments and vice versa if       
  76.             either are necessary.
  77.  
  78. NetWare v2.15 Installation (Custom)
  79.  
  80.             Refer to the NetWare v2.15 Maintenance manual for          
  81.             installation instructions. Before running NETGEN complete   
  82.             the following steps:
  83.  
  84.             1.    NETWORK DRIVE:  Create a directory called            
  85.                   DSK_DRV_.031.
  86.  
  87.                   FLOPPY DRIVE:  Format a diskette with the label      
  88.                   DSK_DRV_031. Use the DOS FORMAT /V command.
  89.  
  90.             2.    NETWORK DRIVE:  Copy the .DSK in the AUXGEN    
  91.                   directory and the .OBJ files into the directory you       
  92.                   created in Step 1.
  93.  
  94.                   FLOPPY DRIVE:  Copy the .OBJ files and the .DSK     
  95.                   files to the newly formatted diskette you created in 
  96.                   Step 1.
  97.  
  98.             3.    Run NETGEN.
  99.  
  100.             4.    NETWORK DRIVE:  Choose "Select Loaded Item" from  
  101.                   the menu and continue with Step 5.
  102.  
  103.                   FLOPPY DRIVE:  Complete the disk driver installation 
  104.                   instructions contained in the Maintenance manual.
  105.                   Then continue with Step 5 below.
  106.  
  107.       Note: As you install new disk drivers, you may see a message      
  108.             similar to the following:
  109.  
  110.                  "Driver 1 has the same type number as Driver 2.
  111.  
  112.                   Replace Driver 1 with Driver 2?"
  113.  
  114.             The drivers do not always appear in the same order,          
  115.             indicating that Driver 1 is not necessarily the new driver.     
  116.             Be sure you select the ESDI shared int 14 driver.
  117.  
  118.             5.    Choose the ESDI shared int 14 driver from the list and
  119.                   press <Enter>. 
  120.  
  121.             6.    Highlight Configuration Option and press <Enter>. 
  122.                   Highlight the option you recorded earlier and press
  123.                   <Enter>.             7.    Repeat Steps 5 and 6, this time choosing the SCSI      
  124.                   shared int 14 driver.
  125.  
  126.             8.    Continue with the file server installation as usual,       
  127.                   following the screen prompts.
  128.  
  129. NetWare v2.2 Installation (Advanced)
  130.  
  131.             1.    Use the DOS LABEL command to format a blank       
  132.                   diskette.  Label the diskette DSK_DRV_031 and         
  133.                   copy the following files onto it:
  134.  
  135.                   o   .OBJ
  136.  
  137.                   o   .DSK
  138.  
  139.             2.    Copy the driver and description files to the              
  140.                   DSK_DRV_031 diskette.
  141.  
  142.             3.    Complete the installation instructions contained in the   
  143.                   documentation for NetWare v2.2, through Step 12 on    
  144.                   page 36.  Then continue with Step 3 below.
  145.  
  146.             4.    Press <Insert>. 
  147.             
  148.             5.    Insert the DSK_DRV_031 diskette into a floppy
  149.                   diskette drive and press <Enter>. 
  150.  
  151.             6.    Choose the ESDI shared int 14 driver from the list and
  152.                   press <Enter>. 
  153.  
  154.             7.    Highlight Configuration Option and press <Enter>. 
  155.  
  156.                   Highlight the option you recorded earlier and press
  157.                   <Enter>. 
  158.  
  159.       Note:  An asterisk (*) next to a selected driver indicates that the   
  160.              option conflicts with other hardware configurations selected. 
  161.              All driver configuration options must correspond to
  162.              actual hardware settings.  Software adjustments must be     
  163.              accompanied by hardware adjustments and vice versa if      
  164.              either are necessary.
  165.  
  166.             8.   Repeat Steps 5 through 7, this time choosing the
  167.                  SCSI shared int 14 driver. 
  168.  
  169.             9.   Press <F10> when the form is complete. 
  170.  
  171.                  This step saves the configurations as entered. Continue  
  172.                  the installation as usual from this point.
  173.  
  174.  
  175. ***************************************************************** 
  176.                     DISCLAIMER  
  177.   
  178. Novell, Inc. makes no representations or warranties with respect to
  179. any NetWare software, and specifically disclaims any express or
  180. implied warranties of merchantability, title, or fitness for a
  181. particular purpose.  
  182.  
  183. Distribution of any NetWare software is forbidden without the
  184. express written consent of Novell, Inc.  Further, Novell reserves
  185. the right to discontinue distribution of any NetWare software.
  186.  
  187. Novell is not responsible for lost profits or revenue, loss of use
  188. of the software, loss of data, costs of re-creating lost data, the
  189. cost of any substitute equipment or program, or claims by any party
  190. other than you.  Novell strongly recommends a backup be made before
  191. any software is installed.   Technical support for this software
  192. may be provided at the discretion of Novell.
  193. *****************************************************************
  194.